Crown: replacing a ~3 year old crown
Prepare in Open Dental
Ready, with warningsPrepared, with warnings: review the risks before approving, then send the claim from Open Dental.
D2740 crown · tooth #5 · 03/25/2026
At risk of denialDo this before submitting
- Confirm the early replacement is justified and documented, or discuss patient responsibility before submitting.
Narrative Every sentence checked against the chart
Porcelain fractured off the existing crown on #5, exposing the metal substructure. Patient reports pain on biting. The crown being replaced on #5 was originally placed 03/02/2023 (3 years before this date of service). Periapical radiograph of #5 taken 02/13/2026. Treatment: D2740 crown on tooth #5, date of service 03/25/2026.
Claim note
Crown #5: narrative and radiograph attached
Would strengthen the claim
- Document the extent of the damage (e.g., % of the crown missing, cusps involved, size of the existing restoration).
- Attach an intraoral photo; photos make fracture and decay findings easier for reviewers to accept.
Attachments
| Item | Status | Detail |
|---|---|---|
| Radiograph | In Open Dental | Periapical radiograph of #5 taken 02/13/2026. Source: Open Dental Imaging: "Periapical 5" (Radiographs), DocNum 6201. |
Documentation checks
| Check | Status | Detail |
|---|---|---|
| Radiograph of tooth #5 within 12 months | Met | Periapical radiograph of #5 taken 02/13/2026 (1.3 months before the date of service). |
| Clinical reason for the crown documented | Met | Porcelain fractured off the existing crown on #5, exposing the metal substructure. |
| Extent of tooth structure loss documented | Not documented | No note describes how much tooth structure on tooth #5 is missing or undermined. |
| Replacement interval (5+ years since prior crown) | Warning | Prior crown placed 03/02/2023, only 3 years before the date of service (eligible again 03/02/2028). Most plans replace crowns once every 5 years, so expect a frequency denial unless a qualifying cause (e.g., fracture) is documented. |
| Initial/replacement flag matches chart history | N/A | Procedure is not flagged as an initial placement. |
| Intraoral photo | Not documented | No intraoral photo of tooth #5 in Open Dental Imaging. |
Evidence used (5 facts)
| ID | Fact | Where it comes from |
|---|---|---|
| C1 | D2740 crown on tooth #5, date of service 03/25/2026. | Procedure D2740 (ProcNum 6001) |
| C2 | Periapical radiograph of #5 taken 02/13/2026. | Open Dental Imaging: "Periapical 5" (Radiographs), DocNum 6201 |
| C3 | The crown being replaced on #5 was originally placed 03/02/2023 (3 years before this date of service). | Procedure D2740: Prosthesis = Replacement, original date 03/02/2023 |
| N1 | Porcelain fractured off the existing crown on #5, exposing the metal substructure."Porcelain fractured off the existing crown on #5, exposing the metal substructure" | Clinical note: D2740 #5 on 03/25/2026 (this procedure) |
| N2 | Patient reports pain on biting."Pt reports pain on biting" | Clinical note: D2740 #5 on 03/25/2026 (this procedure) |
Draft → check → revise loop (1 iteration)
Iteration 1: no issues
Clinical notes read (1, names redacted)
D2740 #5 on 03/25/2026 (this procedure)
Porcelain fractured off the existing crown on #5, exposing the metal substructure. Pt reports pain on biting. Crown prep #5 for zirconia crown. Shade A2. Temp placed.